Brand Name : ICS triplex
Model Number : T7481A
Place of Origin : USA
MOQ : 1
Price : 66USD
Payment Terms : T/T
Supply Ability : in stock
Delivery Time : 2-3 work days
Packaging Details : Brand new and original
Estimated Shipping Size : 3.3x26.4x32.7cm
weight : 1.6 kg
Voltage Range : 18 to 36 VDC
Heat Dissipation : 30 Watts, 101 BTUs/hour
Operating Temperature : 0° to 60° C (32° to 140° F)
Storage Temperature : -40° to 85° C (-40° to 185° F)
Operating Humidity : 0 to 95% relative humidity, non-condensing
Vibration(10 to 55 Hz) : ±0.15mm
![]()
01.Monitored Guarded output modules provide Guarded control and line monitoring for sixteen field loads. Three types of modules are available for interfacing to outputs powered from 24 VDC, 110 VAC, or 120 VDC field power supplies.
02.These modules are referred to as Guarded because each module’s dual-redundant design ensures that no single fault within the module can inadvertently apply power to an output. In addition, the modules monitor the output field wiring for open-circuit and short-circuit faults.
03.Individual output line status is made available to application programs, allowing continuous supervision of output operation and field wiring integrity.
![]()
Output and Fault Tolerance
Sixteen Guarded outputs (arranged in two groups of eight)
Fault-tolerant operation when connected in parallel with another module of the same type
Maintenance and Service
Hot-replaceable for minimal downtime
Fuses accessible from the front panel for easy replacement
Diagnostics and Monitoring
Complete, automatic testing of all output circuits
Automatic line monitoring detects open-circuit and short-circuit field wiring faults
Individual front panel indicators show module fault/active status and shutdown state
Additional indicators display output status and load/fuse fault for each point
Electrical and Safety Compliance
Minimum 2500 V electrical isolation between field and logic circuits
TÜV certified, Risk Class 5
![]()
Each output module is configured using the WINTERPRET I/O Configuration Editor. To configure the module, follow the four steps below:
1. Set the Module Type
Position the cursor on the module slot you wish to define.
Select Set Module Type from the Edit Menu, then choose the appropriate Monitored Guarded Output Module from the list.
2. Edit the Module Definition
Select Edit Module Definition from the Edit Menu.
A dialog box will open, allowing you to define the output point definitions for the module.
3. Configure Single or Dual Mode
With the cursor at the top of the list in the Module Definition dialog, open the Monitored Guarded Output Module Definition dialog by pressing Enter or double-clicking the “(Module)” selection.
If the module is to operate in dual mode (wired in parallel with another module for fault tolerance), check the Dual Mode selection in the dialog box.
Enter the I/O Assembly number (1–16) and I/O Slot number (1–10) of the redundant module. This must be done for each of the two modules operating in dual mode.
4. Edit Each Output Point
From the Module Definition dialog box, select Edit to define a name and description for each output point.
In the Monitored Guarded Output Point dialog, enter the names and values for the configuration fields as required.
![]()
Quality parts. No nonsense.
When you order from us, you know exactly what you're getting.
Stocked Up: We hold a massive inventory of major brand-name parts. If you need it, we likely have it.
100% Legit: Only Brand New & Original items. No refurbished, no fakes.
Tested by Pros: We don't just ship boxes. Our experienced team runs every unit through our testing facility first.
Fast Movers: Prompt delivery is our standard. We pack it safe and get it out the door.
Need a reliable partner? We’re ready.
Miya Zheng
Sales Manager
+86 180 2077 6792
sales@amikon.cn
|
|
ICS Triplex T7481A Monitored Guarded Output Module with 16 Field Loads, Fault-Tolerant Operation Images |